Passer au contenu principal

Working with a PMS3D or SummitEvolution station

In the PMS3D and SummitEvolution editions, rhinoCapture provides neither the stereo view nor the 3D cursor: those of the station are used.

A work session therefore starts with the connection of RhinoCapture to the station, continues with capture — you point in the station, the objects appear in Rhinoceros — and ends with the disconnection. Three commands are enough; the PMS3D edition adds three more to access its dialogs.

Once the connection is established, everything you capture or draw in either software is displayed in the other; the zoom level and the cursor position are synchronized.

Command Name Icon Menu Path
CaptureConnect
command icon
RhinoCapture > Connect

PMS3D · Summit

Menu

RhinoCapture\Connect

If the station is started, the command line displays:

DAT/EM Summit Evolution connected

If a project is open in it, the details of the loaded pair precede this message:

Summit model loaded : 017_071_NAD006800_017_072_NAD006801 (left), X=393 271.72, Y=5 708 215.42, Z=1 535.58, omega=0.070°, phi=-0.161°, kappa=89.817°

DAT/EM Summit Evolution connected

Two other signs confirm the connection:

  • the appearance of a new top view “SummitEvolution” in Rhinoceros. This is the view in which you interact with the station during the capture commands; it displays the cursor, which reflects the position of the 3D mouse;
  • the creation of the capture layers in the current document.

The first time rhinoCapture is launched, if the RhinoCapture layer does not exist in the document, it is created. Depending on the UseAFeatureClassFile setting (see the RhinoCapture.xml appendix), either the layers defined in the feature class file are created under this layer — and the first one becomes the current layer —, or a “default” layer is created and becomes current. All objects captured from the station are placed on the current layer.

⚠️ Only the sublayers of the RhinoCapture layer are displayed in SummitEvolution. Objects placed on other layers remain visible in Rhinoceros, but not in the station’s stereo view.
Command Name Icon Menu Path
CaptureDisconnect
command icon
RhinoCapture > Disconnect

DAT/EM Summit Evolution not connected

Command Name Icon Menu Path
CaptureMoveTo
command icon
RhinoCapture > Move to

Recenters the station’s stereo view on a point picked in Rhinoceros. The command asks for a point in a Rhinoceros view; the station places this point at the center of its stereo view and positions its cursor there, at the elevation of the point. It lets you quickly find in the stereo pair an object spotted in the model, or resume capture at a precise location.

💡 Since the station cursor is moved to the point, at its elevation, a new capture can start without manual repositioning.
Command Name Icon Menu Path
CaptureSendReturnToCommandLine
command icon
RhinoCapture > Send Enter

Sends an Enter key to the Rhinoceros command line. The command is intended to be assigned to a button of the stereo plotting station: it lets you validate a selection, end a capture or accept the default option of a command without leaving the stereo view or going back to the keyboard.

💡 In rhinoCapture, the same result is obtained with a <Keystroke> action in the ControllerConfig.xml file of Oxalis, without an intermediate command.